SLC44A4

ANTIBODY AND ANTIGEN INFORMATION

? »
 

Antibody HPA046977

 

Antibody HPA054176

 

ANTIBODY INFORMATION

Provider

Atlas Antibodies
Sigma-Aldrich
 Atlas Antibodies
Sigma-Aldrich
 

Product name

HPA046977 HPA054176 

Host species

Rabbit Rabbit 

Clonality

pAb pAb 

Purity

Affinity purified using the PrEST-antigen as affinity ligand Affinity purified using the PrEST-antigen as affinity ligand 

Released in version

12 12 

ANTIGEN INFORMATION

Antigen

Recombinant protein fragment Recombinant protein fragment 

Length (aa)

91 69 

Antigen sequence

RQVLYPRNSTGAYCGMGENKDKPYLLYFNIFSCILSSNIISVAENGLQCP
TPQVCVSSCPEDPWTVGKNEFSQTVGEVFYTKNRNFCLPGV
 
MTVITSLQQELCPSFLLPSAPALGRCFPWTNVTPPALPGITNDTTIQQGI
SGLIDSLNARDISVKIFED
 

Matching transcripts

SLC44A4-001 - ENSP00000229729 [100%]
SLC44A4-004 - ENSP00000398901 [100%]
SLC44A4-202 - ENSP00000444109 [84%]
 SLC44A4-001 - ENSP00000229729 [100%]
SLC44A4-004 - ENSP00000398901 [100%]
SLC44A4-202 - ENSP00000444109 [100%]
SLC44A4-201 - ENSP00000364712 [99%]
 

Other gene match

  

ANTIBODY VALIDATION

         Immunohistochemistry

Image

  

Description

Immunohistochemical staining of human bronchus shows strong positivity in ciliated cells of respiratory epithelia.
More information
 Immunohistochemical staining of human fallopian tube shows strong membranous positivity in glandular cells.
More information
 

Retrieval method

HIER pH6 HIER pH6 

Antibody dilution

1:20 1:450 

Literature conformity

No avaliable gene/protein characterization data No avaliable gene/protein characterization data 

RNA consistency

Not done Not done 

         Western Blot

Image

  

Description

Lane 1: Marker [kDa] 250, 130, 95, 72, 55, 36, 28, 17, 10
Lane 2: RT4
Lane 3: U-251 MG
Lane 4: Human Plasma
Lane 5: Liver
Lane 6: Tonsil
More information
 Lane 1: Marker [kDa] 250, 130, 95, 72, 55, 36, 28, 17, 10
Lane 2: RT4
Lane 3: U-251 MG
Lane 4: Human Plasma
Lane 5: Liver
Lane 6: Tonsil
More information
 

Target mass (kDa)

79.3, 70.8, 45.6 79.3, 74.5, 70.8, 45.6 

Antibody dilution

1:140 1:340 

Validation WB

Uncertain: Single band larger than predicted size in kDa (+20%) but partly supported by experimental and/or bioinformatic data Supportive: Single band corresponding to the predicted size in kDa (+/-20%) 

         Protein array

Image

  

Description

Antibody specificity analysis with protein arrays. Predicted and matching interactions are shown in green.
More information
 Antibody specificity analysis with protein arrays. Predicted and matching interactions are shown in green.
More information
 

Antibody dilution

1:1100 1:2750 

Validation PA

Uncertain: Pass with quality comment low specificity (binding to 1-2 PrESTs >15% and <40%). Supportive: Pass with single peak corresponding to interaction only with its own antigen. 
 

ANTIGEN VIEW

? »
 
 
 
SLC44A4-001
 
SLC44A4-004
 
SLC44A4-201
 
SLC44A4-202